Page 8
OPERATING CONTROLS (continued)
6. TERMINAL P1 (continued)
Light (LT)
A 24V DC relay of the appropriate contact voltage can be connected to the light terminal (LT)
and 24V terminal to control external lights by the transmitter button associated with the cour-
tesy light or with any door operation.
Lock (LCK)
When a button programmed for vacation mode is pressed, the door will not respond to any
other transmitters after the door reaches its close position until this mode is reversed.
If there is no transmitter button programmed for vacation mode, then the terminal will function
as a BMS input. When the door reaches its close position, the door will be forced to open and
then opener will freeze until it is powered up again
7. TERMINAL P1
Photo Electric Beam Input (PE)
A link between PE and COM has to be removed when connecting a Photo Electric Beam.
NOTE: The link must not be removed otherwise the opener will not function correctly. Re-
move only when a PE beam is to be connected.
24V Power Supply (24V)
24V output supplies 24V DC 20% ripple at 60mA to power an external receiver or electronic
device, etc.
Open/Stop/Close Input (OSC)
OSC INPUT is used for the connection of a wired switch (momentary contact). This switch
can then be used to open, stop or close the door. Wire the normally open momentary
contact switch to the OSC and COM terminals.