Automatic COBRA Installationshandbuch Seite 17

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 28
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 16
Page 17
PROGRAMMING - Door Travel Limits
SETTING DOOR TRAVEL LIMITS
To code transmitter for setting limits
1. Select Handheld Mode using the LEARN button on the unit.
Display shows (H)andheld (Fig. 16)
2. Within 10 seconds, momentarily press the required button on the
transmitter. The decimal point indicator on the display will
ash and then stay on.
3. Re-press the same button again momentarily, the decimal point
indicator will fl ash and then the display will show the memory
location number for that function ‘Hxx’. The location number
xx will be the fi rst free location number in the memory.
To set limits
4. Engage the traveller into the chain spool.
5. Select Limits mode using the INSTALL button on the unit. Display shows (L)imits (Fig 17).
NOTE: The door and traveller must be engaged with the chain spool. The close position MUST be set fi rst, fol-
lowed by the open position.
6. Press button 4 (Fig. 18), the door will start closing, release the button once you are 1 to 2 cm from your desired
closed limit position. Press button 3 (Fig. 18) for two seconds then release to change to Slow mode ( S will
ash on the display 3 times) .
7. Press button 4 briefl y, each press will enable you to inch the door to your desired closed position (Press button 1
to adjust position if necessary).
8. Once you are happy with the close position press button 2 (Fig. 18) for two seconds, this action will store into
memory the closed limit position. The O will fl ash on the display. The opener is ready for setting the open
position.
9. Press button 1 (Fig. 18), the door will start opening, release the button once you are 1 to 2 cm from your desired
open limit position. Press button 3 for two seconds then release to change to Slow mode (S ashes on the
display 3 times).
10. Press button 1 briefl y. Each press will enable you to inch the door to your desired open position (Press button
4 to adjust position if necessary).
IMPORTANT WARNING: Please be aware that the garage door will start closing automatically once step 11 is
performed. The door will also automatically re-open after fully closing with a small pause between the cycles.
11. Once you are happy with the open position, press button 2 for two seconds, to store in memory the open limit
position. The door will now automatically close and then fully open to calculate the safety obstruction
forces. Please be aware of the above warning.
Resetting Door Limits Positions
Follow Steps 4 to 11 to set new travel limit positions.
Please note that there is no need to re-code the transmitter used for setting the limit positions. After the limits
are set the transmitter will automatically reset to normal operation.
Go to next STEP and test the Safety Obstruction Force.